« Prev | Next»

M8692 • 240W 12VDC Switchmode Power Supply

Print

Cat. Page 274

M8692

  • $155.00
  • 2+ $142.00
  • 4+ $128.00
  • Price per each
  • Includes GST
 

Weight:0.74700Kg

    Northbridge Less than 5pcs
    Balcatta Less than 5pcs
    Cannington Less than 5pcs
    Midland Less than 5pcs
    Myaree Less than 5pcs
    Auburn Less than 5pcs
    Springvale Less than 5pcs
    Airport West Less than 5pcs
    Brisbane Less than 5pcs
    Adelaide Less than 5pcs
    Warehouse In Stock

Last updated 15-03-19 09:20:14

This product has not been viewed until now!

  • Popular
  • Overview
  • Specifications

Overview

Switchmode power supplies offer several significant advantages over traditional linear transformer power supplies.They are far more efficient than their linear counterparts. As they do not use power or mains transformers the equivalent power supply weighs considerably less than traditional types. Physical size is also reduced. Though the power supplies are supplied in a vented steel cabinet they must be installed within a secondary earthed cabinet as the 240V input terminals are exposed.

Features

  • Universal AC input / Full range
  • Protection: Short circuit / Overload / Over voltage
  • Fan cooled
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105C long life electrolytic capacitors
  • Withstand 3000VAC surge
  • High operating temperature up to 70C
  • Withstand 2G vibration test
  • High efficiency, long life and high reliability

Specifications

  • Output
  • DC Voltage: 12V
  • Rated Current: 20A
  • Current Range: 0-20A
  • Rated Power: 240W
  • Ripple & Noise: 150mV p-p
  • Voltage Adjust Range: 10-14V
  • Voltage Tolerance: 1.0%
  • Line Regulation: 0.3%
  • Load Regulation: 0.5%
  • Setup / Rise Time: 800ms / 50ms @ 230VAC
  • Hold Up Time (Typical): 20ms @ 230VAC
  • Input
  • Voltage Range: 88-264VAC 124-370VDC
  • Frequency Range: 47-63Hz
  • Efficiency (Typical): 86%
  • AC Curremt (Typical): 3.6A/115VAC, 1.8A/230VAC
  • Inrush Current (Typical): Cold Start 40A/230VAC
  • Leakage Current: <2mA/240VAC
  • Protection
  • Overload: 105-135% rated power output
  • Over Voltage: 14.7-17.5V
  • Protection Type: Shutdown output voltage, re-power on to recover
  • Environment
  • Working Temperature: -20 - +70C
  • Working Humidity: 20-90% RH non condensing
  • Temperature Coefficient: 0.03%/C(0-50C)
  • Vibration: 10-500Hz, 2G 10 minutes/1cycle, period for 60 minutes. Each along X,Y,Z, axis
  • Dimensions: 190L x 93W x 50H mm
  • Weight: 0.8kg

*Specifications are subject to change without notice.