Description |
Downloads |
Specs |
Ordering |
|
 |
M5015C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
 |
M1005 ROHS
|
|
|
|
Impedance: 600 Ohm line, 600 Ohm or 150 Ohm equip.
Turns Ratio: 1:1
Max Level: +20dBm @ 200Hz
Insertion Loss: 1dB max @ 0dBm
Frequency Response: 200Hz - 3KHz
Return Loss: >15dB, 200Hz - 3kHz
Max Unbalanced DC: 5mA
Proof Test: 3.5kV RMS
Dimension: 26L x 21H x 19W
Weight: 25 gms
PCB hole size: 1.3mm |
 |
M2158C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 72VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Powertran EI-Core 240V AC mains transformer with 3A single tap secondary configuration. 24V secondary voltage available at 3A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. |
 |
M5025C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
 |
MA5417 |
|
|
|
Primarily to be used as part of our K 5125 20 Watt Class A Amplifier Kit. We can now offer this component as a standalone item for those who wish to build this amplifier in a different housing to that supplied with the kit.
|
 |
M4909B |
|
- Primary voltage: 240V AC
- Secondary voltage: 9V (parallel), 18V (series)
- Secondary current: 3.3A (parallel), 1.6A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
 |
M5115C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 15V secondaries. 80VA rated.
|
 |
M4909C |
|
- Low profile design is suitable for use inside our 1RU 19” rack enclosures.
- 30VA series models have potted epoxy centre core for easy mounting.
- Lower electrically induced noise demanded by compact equipment.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
 |
M7018A ROHS
|
|
- Sec. V: 9+9
- Sec. Parallel: 0.33A
- Sec. Series: 0.16A
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA rating: 3VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Regulation: ˜23%
- Weight: ˜95g
- PCB hole size: 0.8mm
- Thermal Fuse: Internal 115°C
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
 |
M4324A |
|
- Sec. V: 12+12
- Sec. Parallel: 0.82A
- Sec. Series: 0.41A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
M4630A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for ideal for high performance, low noise circuits. |
 |
M7270 ROHS
|
|
- Primary voltage: 230V AC or 240V AC @ 50Hz
- Total VA Rating: 10VA
- Insulation: Class A (105°C)
- Magnetising Current: <30mA
- Temperature Rise: <65°C
- Regulation: 11%
- Weight: 250g
- PCB Hole Size: 1.2mm
- Secondary Voltage: 15 + 15
- Parallel : 0.66A
- Series: 0.33A
- Standard AS/NZS 61558.2.6 Certified
|
|
Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |
 |
M5345A |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 45V secondaries. 160VA rated.
|
 |
M5125C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 25V secondaries. 80VA rated.
|
 |
M5530C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 30V secondaries. 300VA rated.
|
 |
M4624A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 30VA
- Insulation: Class B (130°C)
- Magnetising current: <30mA
- Temperature rise: <85°C
- External AC fuse (required): 250mA
- Thermal Fuse: 84°C
- Regulation: ≈16%
- Weight: ≈450g
- PCB hole size: 2mm
- Approval: SAA151379EA
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
M5518C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
300VA toroidal transformer |
 |
M5018C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. 18+18V. |
 |
M2156C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 30VA
- Insulation: Class E (120°C)
- Magnetising current: <65mA
- Temperature rise: <60°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
|
|
Powertran EI-Core 240V AC mains transformer with 2A multi tapped secondary configuration. 0V, 6V, 9V, 12V and 15V secondaries are available at 2A current output. Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS 61558.2.6. |
 |
M2852L |
|
- Primary voltage: 240V AC
- Total VA rating: 3.78VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
|
|
Primary and secondary fitted with 200mm fly leads. |
 |
M4330A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <85°C
- External AC fuse (required): 100mA
- Thermal fuse: 84°C
- Regulation: ≈20%
- Weight: ≈210g
- PCB hole size: 2mm
- Approval: SAA151379EA
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
M1010 ROHS
|
|
|
|
Impedance: 600 Ohm line, 600 Ohm or 150 Ohm equip.
urns Ratio: 1:1
Max Level: +20dBm @ 200Hz
Insertion Loss: 1.8dB max @ 0dBm
Frequency Response: 300Hz - 3kHz
Return Loss: >15dB, 300Hz - 3kHz
Max Unbalanced DC: 80mA
Proof Test: 3.5kV RMS
Dimension: 35L x 17H x 29W
Weight: 50 gms
PCB hole size: 1.2mm |
 |
M5109 |
|
- Primary voltage: 240V AC
- Secondary voltage: 9V (parallel), 18V (series)
- Secondary current: 8.8A(parallel) 4.4A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
Certificate No.: CS 815/Q |
 |
M5315C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Note: Must be used with a 3A external AC fuse. |
 |
M6672C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 30VA
- Insulation: Class E (120°C)
- Magnetising current: <80mA
- Temperature rise: <65°C
- Regulation: ˜8%
- Recommended primary AC fuse: 500mA
- Weight: ˜1kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042029
- AS3108 approval: CS/814/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |