Description |
Downloads |
Specs |
Ordering |
|
|
M6672C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 30VA
- Insulation: Class E (120°C)
- Magnetising current: <80mA
- Temperature rise: <65°C
- Regulation: ˜8%
- Recommended primary AC fuse: 500mA
- Weight: ˜1kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042029
- AS3108 approval: CS/814/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |
|
M2854L |
|
- Primary voltage: 240V AC
- Total VA rating: 3.6VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2854C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 3.6VA
- Insulation: Class E (120°C)
- Magnetising current: <40mA
- Temperature rise: <65°C
- Regulation: ˜12%
- AC fuse: Not required (fitted internally)
- Weight: ˜235g
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
- Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
|
|
Primary and secondary fitted with 200mm fly leads. |
|
M2158L |
|
- Primary voltage: 240V AC
- Total VA rating: 72VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
|
|
Powertran EI-Core 240V AC mains transformer with 3A single tap secondary configuration. 24V secondary voltage available at 3A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. |
|
M2158C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 72VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Powertran EI-Core 240V AC mains transformer with 3A single tap secondary configuration. 24V secondary voltage available at 3A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. |
|
M2190L |
|
- Primary voltage: 240V AC
- Total VA rating: 120VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ˜10%
- Recommended primary AC fuse: 500mA
- Weight: ˜2.2kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
- AS/NZS 61558.2.6 approval: Q042094
- AS3108 approval: CS/990/Q
|
|
Primary fitted with 200mm fly leads. Secondary taps have solder tags. |
|
M2190C NEW
|
|
- Primary voltage: 240V AC
- Total VA rating: 120VA
- Insulation: Class E (120°C)
- Magnetising current: <85mA
- Temperature rise: <65°C
- Regulation: ≈10%
- Recommended primary AC fuse: 500mA
- Weight: ≈1.4kg
- Primary connection: 200mm fly leads
- Secondary connection: 200mm fly leads
|
|
Powertran EI-Core 240V AC mains transformer with 5A single tap secondary configuration. |
|
M9379A |
|
|
|
24VAC @ 900mA
Unit has bare ends (no tip fitted)
MEPS Approved. |
|
M9381 |
|
|
|
24VAC @ 1.87A
Unit has bare ends (no tip fitted)
MEPS Approved. |
|
M9393B |
|
- Australian standards compliant
- Suitable for a range of electronic devices
- Compatible with Australian mains power point
|
|
24V DC Switchmode Plugpack Supplied with reversible polarity 2.1mm DC tip. Compact design with high current regulated output. |
|
MA8241 |
|
- Australian standards compliant
- Suitable for a range of electronic devices
- Compatible with Australian mains power point
|
|
24V DC Switchmode Plugpack Supplied with fixed screw on positive 2.1mm DC tip. Compact design with high current regulated output. |
|
M8968C |
|
- Australian standards compliant
- Suitable for a range of electronic devices
- Compatible with Australian mains power point
|
|
24V DC Switchmode Plugpack Supplied with fixed 2.1mm DC tip (tip positive). Compact design with high current regulated output. Energy authority approved. MEPS approved.
24VDC @ 1A. |
|
MB8968C |
|
- MEPS efficiency level V
- Australian standards compliant
- Suitable for a range of electronic devices
- Compatible with Australian mains power point
|
|
24V DC, 1 Amp switch mode plug pack. Supplied with a fixed positive to tip 2.5mm DC jack (2.5ID x 5.5OD x 10L). |
|
M8969 NEW
|
|
- MEPS efficiency level V
- Australian Standards Compliant
- Suitable for a range of electronic devices
- Compatible with Australian mains power point
|
|
24V DC 2A switch mode plug pack. |
|
M8972A |
|
- Australian standards compliant
- Suitable for a range of electronic devices
|
|
24V DC Switchmode Powerpack. Super-compact regulated power supplies. Supplied with fixed 2.1mm DC jack. 100-240V AC input via IEC C13 socket. Energy authority approved. MEPS approved. Dimensions: 143Wx58x34Dmm. |
|
M8971A NEW
|
|
- MEPS efficiency level: V
- Australian standards compliant
- Suitable for a range of electronic devices
|
|
Super compact regulated power supply. 100V - 240V ac input. Energy authority approved and MEPS approved. Supplied with a fixed 2.1mm dc jack. |
|
M8973A |
|
|
|
Super-compact regulated power supplies. Energy authority approved. MEPS approved. All models are Energy Authority approved and suitable for shipping with other OEM products. Require P 8410C IEC lead. Dimensions: 167 x 65 x 40mm. |
|
M5325C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 25V secondaries. 160VA rated.
|
|
M5525C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
25+25V 300VA toroidal transformer. |
|
M5725C |
|
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Toroidal transformers are becoming increasingly popular due to their improved magnetic properties and also that they can be made to a lower profile than a standard solenoid core transformer, allowing for equipment of similar power to be of a lower profile such as rack mounted devices. |
|
M5125C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 25V secondaries. 80VA rated.
|
|
M5025A |
|
- Primary voltage: 240V AC
- Secondary voltage: 25V (parallel), 50V (series)
- Secondary current: 2A (parallel), 1A (series)
- Regulation: Better than 10%
- Maximum temperature rise: 75°C
- Dielectric strength: 4000V for 1 Minute
- Insulation class: Class B (130ºC)
- Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available.
- Minimum order quantity applies.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
M5025C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
|
P8293 |
|
- Fitted with 3 pin mains connectors.
- 25 metre length.
- 3 x 1mm2 conductors
- Electrical authority approved.
- AS/NZS standards compliant for connectors & cable.
|
|
Heavy duty black plugs and lead. 25m |
|
M8730 |
|
- Screw terminals for inputs and outputs
- Wide operating input voltage 90 – 264VAC, 47 – 63Hz
- Excellent output regulation from no load to full load
- High efficiency
- Overload and short circuit protection
- Inbuilt EMI filter to reduce noise radiation
- EMC approved
|
|
Switchmode power supplies offer several significant advantages over traditional linear transformer power supplies.They are far more
efficient than their linear counterparts. As they do not use power or mains transformers the equivalent power supply weigh |