|  | Description | Downloads | Specs | Ordering |  | |  | W2426    |  | Conductor
Material: Tinned Copper
AWG: 3.96mm2×1C (11AWG)
Construction: 56/0.30mm±0.01mm
Stranded Diameter: 2.59mm
Jacket
Material: PVC
Average Thickness: 0.80mm
Cable Diameter : 4.2±0.1mm
Colour
Jacket: Red
Physical and Electrical Characteristics
Rated Voltage: 600VAC
Rated Temperature: 1.05℃
Rated Current: 30 Amps
Maximum DC Resistance: 4.7Ω/km
Tensile Strength: ≥10.3Mpa (Insulation and Jacket)
Elongation: ≥100% upward (Insulation)
Dielectric Strength: 2kV/min (Insulation in water)
Mechanical Characteristics
Again Condition: 120±1℃/120hr No Crack
Cold Blend: -20±2℃/4hr No Crack
Packaging
Drum Sizes: 10M
 |  | Tinned for corrosion resistance. Ideal for auto and marine wiring jobs. Convenient mini-reels. 30A 56/0.30mm | 
|  | W2427    |  | Conductor
Material: Tinned Copper
AWG: 3.96mm2×1C (11AWG)
Construction: 56/0.30mm±0.01mm
Stranded Diameter: 2.59mm
Jacket
Material: PVC
Average Thickness: 0.80mm
Cable Diameter : 4.2±0.1mm
Colour
Jacket: Black
Physical and Electrical Characteristics
Rated Voltage: 600VAC
Rated Temperature: 1.05℃
Rated Current: 30 Amps
Maximum DC Resistance: 4.7Ω/km
Tensile Strength: ≥10.3Mpa (Insulation and Jacket)
Elongation: ≥100% upward (Insulation)
Dielectric Strength: 2kV/min (Insulation in water)
Mechanical Characteristics
Again Condition: 120±1℃/120hr No Crack
Cold Blend: -20±2℃/4hr No Crack
Packaging
Drum Sizes: 10M
 |  | Tinned for corrosion resistance. Ideal for auto and marine wiring jobs. Convenient mini-reels. 30A 56/0.30mm. | 
|  | W2510  ROHS
  |  | 1.27mm Pitch. 
Number of strands in each conductor: 7/0.127mm
30m Roll
 |  | 1.27mm Pitch. 
Conductors 10 x 0.12mm.
30m Roll | 
|  | W2516  ROHS
  |  | 1.27mm Pitch. 
Number of strands in each conductor: 7/0.127mm
30m Roll
 |  | 1.27mm Pitch. 
Conductors 10 x 0.12mm.
30m Roll | 
|  | W2524  ROHS
  |  | 1.27mm Pitch. 
Number of strands in each conductor: 7/0.127mm
30m Roll
 |  | 1.27mm Pitch. 
Conductors 10 x 0.12mm.
30m Roll | 
|  | W2610  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 10 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 10 Way. Grey insulation. | 
|  | W2614  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 14 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 14 Way. Grey insulation. | 
|  | W2616  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 16 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 16 Way. Grey insulation. | 
|  | W2620  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 20 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 20 Way. Grey insulation. | 
|  | W2625  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 20 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 25 Way. Grey insulation. | 
|  | W2626  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 26 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 26 Way, 1.27mm pitch. Grey insulation. | 
|  | W2634  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 34 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 34 Way. Grey insulation. | 
|  | W2640  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 40 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 40 Way. Grey insulation. | 
|  | W2650  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 50 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 50 Way. Grey insulation. | 
|  | W2710  ROHS
  |  | Size:	7/0.127
Outside Diameter: 	5.0mm
Conductor Area:	0.09mm2
Conductor Gauge:	28AWG
Temperature Rating: 90ºC
Roll Size: 100m
Cores: 6
 |  | 100% Screened cable with tinned drain wire. Ideal for computer systems, etc. | 
|  | W2712  ROHS
  |  | Size: 7/0.127
Outside Diameter: 6.0mm
Conductor Area: 0.09mm2
Conductor Gauge: 28AWG
Temperature Rating: 90ºC
Roll Size: 100m
Cores: 9
 |  | 100% Screened cable with tinned drain wire. Ideal for computer systems, etc. | 
|  | W2745    |  | Cable Specification: CAT6A Solid Core UTP
Cable Length: 350 meters
Conductor
Construction (mm): 1/0.508±0.005
Material: BARE COPPER
Cabling OD (mm): 0.508
Insulation
Material: HDPE
OD (mm): 0.90±0.05
Avg. Thickness (mm): 0.18
Color: 1, 2, 3, 4
Cores Twisted: Yes
Assemble: Cabling OD (mm): 5.00(Ref.) + Filler
Jacket
Material: PVC (Bright)
OD (mm): 6.20±0.20
Avg. Thickness (mm): 0.6
Color: BLACK 3C
Jet Print Color: WHITE
Electrical
Voltage rating: 30V
Temperature: 60°
Dielectric strength: AC-500V/MIN
Insulation resistance: 100M (OHMS*KM MIN at 20°)
 |  | U/UTP (unshielded twisted pair) network cable with UV stabilised sheath for exterior use | 
|  | W2759  ROHS
  |  | Size: 8 x 1/0.50 24AWG
Outside Diameter: 6mm 
Conductor Area: 0.20mm2 
Roll Size: 100m Pull Box
 |  | ACMA approved. Industry standard single conductor UTP (unshielded twisted pair) computer network cable. Supplied in convenient "Pull Box" for easy installation and neat cable storage. | 
|  | W2761  ROHS
  |  | Colour: Blue
Size: 8 x 1/0.50 24AWG
Outside Diameter: 6mm 
Conductor Area: 0.20mm2 
Roll Size: 305m Pull Box
 |  | ACMA approved. Industry standard single conductor UTP (unshielded twisted pair) computer network cable. Supplied in convenient "Pull Box" for easy installation and neat cable storage. Metre marked. Ringpoint trace marked for easy core identification. | 
|  | W2762  ROHS
  |  | Colour: Pink
Size: 8 x 1/0.50
Outside Diameter: 6mm
Conductor Area: 0.20mm2
Roll Size: 305m Pull Box
 |  | ACMA approved. Industry standard single conductor UTP (unshielded twisted pair) computer network cable. Supplied in convenient "Pull Box" for easy installation and neat cable storage. Metre marked. Ringpoint trace marked for easy core identification. | 
|  | W2765  ROHS
  |  | Size: 8 x 1/0.55MM 23AWG
Outside Diameter: ²6mm
Conductor Area: 0.20mm2
Roll Size: 100m pull box
 |  | ACMA approved. Industry standard single conductor UTP (unshielded twisted pair) computer network cable. | 
|  | W2980  ROHS
  |  | Size: 2 x 96/0.1 
Dimensions: 2.5 x 12.5 
Conductor area: 0.75mm2 
Conductor gauge: 18AWG 
Temperature rating: 90°C
Roll Size: 50m
 |  | Oxygen free super flat speaker cable perfect for installing under carpet or along skirting boards. Great for discrete custom installs. | 
|  | W2981  ROHS
  |  | Size: 2 x 96/0.1 
Dimensions: 2.5 x 12.5 
Conductor area: 0.75mm2 
Conductor gauge: 18AWG 
Temperature rating: 90°C
Roll Size: 100m
 |  | Oxygen free super flat speaker cable perfect for installing under carpet or along skirting boards. Great for discrete custom installs. | 
|  | W2988    |  |  |  | A flat copper tape ideal for running speaker cable underneath carpets. Can be folded to run around corners. | 
|  | W2995  ROHS
  |  | Conductor
Material: Bare Copper
AWG: 25AWG
Construction: 16/0.12mm ± 0.008mm
Stranded Diameter: 0.55mm
Insulation
Material: SR-PVC
Average Thickness: 0.33mm
Insulation Diameter: 1.30mm ± 0.008mm
Core Assembly: 2 Cores
Shielded
Material: Bare Copper
Construction: 34/0.12mm ± 0.008mm
Diameter: 1.54mm (each shielded)
Jacket
Material: PVC
Average Thickness: 0.92mm
Cable Diameter: 3.6 x 7.2 ± 10mm
Colour
Insulation: Red/White
Jacket: Black
Physical & Electrical Characteristics
Maximum DC Resistance: 11.1Ω/100m @ 20°C (max)
Tensile Strength (Insulation): ≥ 2.11kgf/mm2
Tensile Strength (Jacket): ≥ 1.05kfg/mm2
Elongation (Insulation & Jacket): ≥ 100%
Mechanical Characteristics
Cold Blend: -20 ± 2°C/4hr No Crack
Packaging
Drum Size: 100m
 |  | High quality shielded audio cable suitable for use in professional and domestic sound applications. |