|  | Description | Downloads | Specs | Ordering |  | |  | W0400    |  | Copper Thickness: 0.1mm
Width: 18mm
Insulation: 0.125mm PET Plastic
Temperature Rating: 100°C
Resistance: 2 Ohms per 100m. 
Roll Length: 50m
 |  | A flat copper tape for building hearing loops encapsulated in a clear PET insulation. Can be folded to run around corners. | 
|  | W2510  ROHS
  |  | 1.27mm Pitch. 
Number of strands in each conductor: 7/0.127mm
30m Roll
 |  | 1.27mm Pitch. 
Conductors 10 x 0.12mm.
30m Roll | 
|  | W2516  ROHS
  |  | 1.27mm Pitch. 
Number of strands in each conductor: 7/0.127mm
30m Roll
 |  | 1.27mm Pitch. 
Conductors 10 x 0.12mm.
30m Roll | 
|  | W2524  ROHS
  |  | 1.27mm Pitch. 
Number of strands in each conductor: 7/0.127mm
30m Roll
 |  | 1.27mm Pitch. 
Conductors 10 x 0.12mm.
30m Roll | 
|  | W2610  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 10 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 10 Way. Grey insulation. | 
|  | W2614  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 14 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 14 Way. Grey insulation. | 
|  | W2616  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 16 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 16 Way. Grey insulation. | 
|  | W2620  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 20 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 20 Way. Grey insulation. | 
|  | W2625  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 20 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 25 Way. Grey insulation. | 
|  | W2626  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 26 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 26 Way, 1.27mm pitch. Grey insulation. | 
|  | W2634  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 34 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 34 Way. Grey insulation. | 
|  | W2640  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 40 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 40 Way. Grey insulation. | 
|  | W2650  ROHS
  |  | Conductor
Size: 28AWG (0.89mm2)
Material: tinned copper
Construction: 7/0.127mm
Insulation
Material: Fire resistant PVC 105ºC
Average thickness: 0.26mm
Minimum thickness: 0.18mm
Diameter: 50 x 1.29±0.15mm
Colour: grey (edge with red trace)
Electric
Conductor resistance: max. 237Ω/km, 20ºC
Insulation resistance: min. 100MΩ/km, 20ºC
Capacitance: 60pF/m (G-S-G), 42pF/m (G-S)
Inductance: 1.45µH/m
Impedance: 100±10Ω (G-S-G)
Propagation delay time 5.0ns/m
Spark test 2500V
Dielectric strength: min. 2kV in 1 minute
Rating voltage: max. 300V
Rating temperature: -20ºC to 105ºC
Standard: UL2651/CSA C22.2 No. 210.2
 |  | 50 Way. Grey insulation. |