Description |
Downloads |
Specs |
Ordering |
|
 |
M5345A |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Efficient toroidal transformer with 45V secondaries. 160VA rated.
|
 |
M5012C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
 |
M5025C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
 |
M5015C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 50VA transformers will fit inside our 1 Unit 19" rack cases |
 |
M5009C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. |
 |
M5018C |
|
- Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19" rack enclosures. 18+18V. |
 |
M4330A |
|
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class B (130°C)
- Magnetising current: <20mA
- Temperature rise: <85°C
- External AC fuse (required): 100mA
- Thermal fuse: 84°C
- Regulation: ≈20%
- Weight: ≈210g
- PCB hole size: 2mm
- Approval: SAA151379EA
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
M4324A |
|
- Sec. V: 12+12
- Sec. Parallel: 0.82A
- Sec. Series: 0.41A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
M8972A |
|
- Australian standards compliant
- Suitable for a range of electronic devices
|
|
24V DC Switchmode Powerpack. Super-compact regulated power supplies. Supplied with fixed 2.1mm DC jack. 100-240V AC input via IEC C13 socket. Energy authority approved. MEPS approved. Dimensions: 143Wx58x34Dmm. |
 |
M4312A |
|
- Sec. V: 6+6
- Sec. Parallel: 1.67A
- Sec. Series: 0.83A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
6+6V 10VA Potted Toroidal Transformer. |
 |
P8164 NEW
|
|
|
|
Ideal for the work bench, this 2 way power extension board features 2 x type A USB chargers and 20W USB type C PD charging output. Plus a 10W wireless charger holder to keep your phone charged up while you work. |
 |
M8865 NEW
|
|
- Power delivery passthrough up to 100W.
- Portable and lightweight design.
- 5 way USB type C charging up to 20W per port (dependant on connected power supply).
- Weighs less than 100 grams!
|
|
Ideal for the workbench, the office or even at home. This compact and portable 5 port USB C extension charger hub provides multiple ports for charging devices up to a total output of 100W. |
 |
M4315A |
|
- Sec. V: 7.5+7.5
- Sec. Parallel: 1.3A
- Sec. Series: 0.66A
- Primary voltage: 2 x 120V AC
- Total VA rating: 10VA
- Insulation: Class A (105°C)
- Magnetising current: <20mA
- Temperature rise: <65°C
- Recommended AC Fuse: 100mA
- Regulation: ˜20%
- Weight: ˜210g
- PCB hole size: 2mm
- AS/NZS 61558.2.6 approval: Q99396
- Note: Must be used with a standard 100mA external AC fuse
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
D2322A NEW
|
|
|
|
This ultra-slim desk mount 15W wireless charging pad offers convenient device charging for your workspace. It fits into a 60mm diameter desk hole and provides cable free charging for your phone while you work. Includes power adaptor and USB cable - nothing more to buy! |
 |
M4912C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
 |
M4918C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
 |
M4909C |
|
- Low profile design is suitable for use inside our 1RU 19” rack enclosures.
- 30VA series models have potted epoxy centre core for easy mounting.
- Lower electrically induced noise demanded by compact equipment.
|
|
Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. |
 |
M4915C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 30VA transformers will fit inside our 1 Unit 19" rack cases. |
 |
M4925C |
|
- Supplied with 1 rubber washer, bolt and nut.
- Lower electrically induced noise demanded by compact equipment.
- High efficiency enabling conservative rating whilst maintaining size advantages.
- The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
|
|
These 30VA transformers will fit inside our 1 Unit 19" rack cases.
|
 |
M4615 |
|
|
|
Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for |
 |
D2321 NEW
|
|
|
|
A stylish bedside or desktop radio alarm clock with in-built 15W wireless charging for your phone. |
 |
M2170C NEW
|
|
- Primary Voltage: 240V AC
- Total VA Rating: 100VA
- Insulation: Class E (120°C)
- Magnetising Current: <85mA
- Temperature Rise: <70°C
- Regulation: ˜14%
- Recommended primary AC Fuse: 500mA
- Weight: ˜1.6kg
- Primary connection: 200mm fly leads
- Secondary connection: Solder tags
- AS/NZS 61558.2.6 approval: Q042028
- AS3108 approval: CS/813/Q
|
|
Powertran EI-Core 240V AC mains transformer with 6A dual multi tapped secondary configuration. Two sets of 0V, 12V and 15V secondaries are available at a maximum current of 6A (max current when secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS |
 |
M6010 |
|
|
|
Typically used for garden lighting and water feature pumps these power supplies are ideal for outdoor use. |
 |
M6014 |
|
|
|
Typically used for garden lighting and water feature pumps these power supplies are ideal for outdoor use. |
 |
M8730 |
|
- Screw terminals for inputs and outputs
- Wide operating input voltage 90 – 264VAC, 47 – 63Hz
- Excellent output regulation from no load to full load
- High efficiency
- Overload and short circuit protection
- Inbuilt EMI filter to reduce noise radiation
- EMC approved
|
|
Switchmode power supplies offer several significant advantages over traditional linear transformer power supplies.They are far more
efficient than their linear counterparts. As they do not use power or mains transformers the equivalent power supply weigh |