|  | Description | Downloads | Specs | Ordering |  | |  | A0300A    |  | Power Rating: 220V - 240VAC
Power Handling: 2400W
Max. Load Current: 10AMP	 
Plug side rating: 250V~10A
Socket side: 240V~10A.
WARNING: This adapter does NOT convert voltages. For use with 240VAC only.
 |  | Allows appliances from all over the world to be plugged into Australian outlets. Use on almost any appliance, such as mobile phone chargers, shavers, irons or laptops.
Suits appliances from most countries. | 
|  | A0300B  NEW
  |  | Power Rating: 220V - 240VAC
Power Handling: 2400W
Max. Load Current: 10AMP	 
Plug side rating: 250V~10A
Socket side: 240V~10A.
WARNING: This adapter does NOT convert voltages. For use with 240VAC only.
 |  | Allows appliances from all over the world to be plugged into Australian outlets. Use on almost any appliance, such as mobile phone chargers, shavers, irons or laptops. Suits appliances from most countries. | 
|  | A0304A    |  | Rating: 100V - 240VAC
Power Handling: 2400W
Max. Load Current: 10AMP	 
WARNING: This adapter does NOT convert voltages. 
 |  | This travel adaptor is most commonly used in the following countries: United States of America and Japan | 
|  | A0305A    |  | Rating: 100V - 240VAC
Power Handling: 2400W
Max. Load Current: 10AMP	 
WARNING: This adapter does NOT convert voltages.
 |  | This travel adaptor is most commonly used in the following countries: United States of America and Canada | 
|  | A0306A    |  | Power Rating: 220V - 240VAC
Power Handling: 2400W
Max. Load Current: 10AMP	
Pin diameter: 4.76mm per pin 
WARNING: This adapter does NOT convert voltages. For use with 240VAC only.	 
 |  | On your next holiday don't forget a travel power adaptor to keep you devices fully charged while you're away. This Bali power adapter also works across most parts of Europe.  Australia / NZ (Type I) to EU (Type F) plug conversion. | 
|  | A0307A    |  | Power Rating: 220V - 240VAC
Power Handling: 2400W
Max. Load Current: 10AMP	 
WARNING: This adapter does NOT convert voltages. For use with 240VAC only.	 
 |  | This travel adaptor is most commonly used in the following countries: Great Britain, Ireland, Singapore, Hong Kong, Middle East (parts), Asia and Africa | 
|  | A0308A    |  | Power Rating: 220V-240V
Power Handling: 2400W
Max. Load Current: 10AMP	 
Plug side rating: 250V~10A
Socket side: 240V~10A.
WARNING: This adapter does NOT convert voltages. For use with 240VAC only.	 
 |  | This adapter is ideally used for overseas appliances in Australia and New Zealand | 
|  | A0319A  NEW
  |  |  |  | A comprehensive travel charger to keep all your portable devices charged while at home or overseas! | 
|  | A0323  NEW
  |  |  |  | A comprehensive all-in-one USB travel charger to keep all your portable devices charged while at home or overseas! It features 65W USB C power delivery output for laptops, mag safe compatible wireless charging for your phone and a standard USB A QC3.0 output for simultaneous charging of up to 3 devices. | 
|  | A0346    |  | Kit includes 1 RF remote + 1 outlets
RF Remote control means line-of-sight is not necessary
Outlets work hidden behind equipment and cabinets!
Outlet's channel is programmable (CH1-4)
Multiple outlets can share the same channel to be controlled simultaneously
Saves stand-by power
Saves from your electricity bill
Can be used in conjunction with a power board
Built-in receiver memory stores data for up to 10 years
Turn individual receivers on or off or a single button to turn all receivers on or off at the same time
 |  | Cut standby 240V power usage around the home and office by switching appliances off at the wall via remote control. Easy inline connection between the GPO and your appliance. | 
|  | A0347    |  | Outlets work hidden behind equipment and cabinets!
Outlet's channel is programmable (CH1-4)
Multiple outlets can share the same channel to be controlled simultaneously
Saves stand-by power
Saves from your electricity bill
Can be used in conjunction with a power board
Built-in receiver memory stores data for up to 10 years
Turn individual receivers on or off or a single button to turn all receivers on or off at the same time
 |  | Cut standby power usage around the home and office by switching appliances off at the wall via remote control. Easy inline connection between the GPO and your appliance | 
|  | D2321  NEW
  |  |  |  | A stylish bedside or desktop radio alarm clock with in-built 15W wireless charging for your phone. | 
|  | D2322A  NEW
  |  |  |  | This ultra-slim desk mount 15W wireless charging pad offers convenient device charging for your workspace. It fits into a 60mm diameter desk hole and provides cable free charging for your phone while you work. Includes power adaptor and USB cable - nothing more to buy! | 
|  | D2324    |  |  |  | This 15W wireless phone charger stand is ideal for home or office. | 
|  | D2327    |  | QI Standard.
Includes USB type A to type C cable
Inbuilt over-voltage, under-voltage and short circuit protection  
 |  | Say goodbye to charging cables! Got two phones with wireless charging. This handy USB charging pad will charge both devices at once. | 
|  | M1124A    |  | 	 	 For 100V line use, connect in series, ie. join pink & yellow.  Use purple & brown.
 |  | High power toroidal transformer for audio use. Input and output windings can be reversed. | 
|  | M2152    |  | 	 Primary voltage:	240V AC
Total VA rating:	12.5VA
Insulation:	Class E (120°C)
Magnetising current:	<45mA
Temperature rise:	<65°C
Regulation:	˜11%
Recommended AC fuse: 250mA
Weight:	˜561g
Primary connection:	200mm fly leads
Secondary connection: 500mm fly leads
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
Secondary Voltages Available: Voltage :12.5V / Current : 1A
 |  | Powertran EI-Core 240V AC mains transformer with 1A centre tapped secondary configuration. 6.25V and 12.5V secondary voltages available at 1A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. | 
|  | M2152C  NEW
  |  | 	 Primary voltage:	240V AC
Total VA rating:	12.5VA
Insulation:	Class E (120°C)
Magnetising current:	<45mA
Temperature rise:	<65°C
Regulation:	˜11%
Recommended AC fuse: 250mA
Weight:	˜561g
Primary connection:	200mm fly leads
Secondary connection: 490mm fly leads
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
Secondary Voltages Available: Voltage :12.5V / Current : 1A
 |  | Powertran EI-Core 240V AC mains transformer with 1A centre tapped secondary configuration. 6.25V and 12.5V secondary voltages available at 1A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. | 
|  | M2155C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	15VA
Insulation:	Class E (120°C)
Magnetising current:	<60mA
Temperature rise:	<60°C
Regulation:	˜10%
Recommended primary AC fuse:	250mA
Weight:	˜555g
Primary connection:	200mm fly leads
Secondary connection:	Solder tags
 |  | Primary fitted with 200mm fly leads. Secondary taps have solder tags. | 
|  | M2156C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	30VA
Insulation:	Class E (120°C)
Magnetising current:	<65mA
Temperature rise:	<60°C
Regulation:	˜10%
Recommended primary AC fuse:	500mA
Weight:	˜1kg 
Primary connection:	200mm fly leads
Secondary connection:	Solder tags
 |  | Powertran EI-Core 240V AC mains transformer with 2A multi tapped secondary configuration. 0V, 6V, 9V, 12V and 15V secondaries are available at 2A current output. Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS 61558.2.6. | 
|  | M2158C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	72VA
Insulation:	Class E (120°C)
Magnetising current:	<85mA
Temperature rise:	<65°C
Regulation:	˜10%
Recommended primary AC fuse:	500mA
Weight:	˜1.4kg
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
 |  | Powertran EI-Core 240V AC mains transformer with 3A single tap secondary configuration. 24V secondary voltage available at 3A current output. Primary and secondaries fitted with 200mm flyleads. Fully electrical authority approved for AS/NZS 61558.2.6. | 
|  | M2165C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	60VA
Insulation:	Class E (120°C)
Magnetising current:	<85mA
Temperature rise:	<65°C
Regulation:	˜10%
Recommended primary AC fuse:	500mA
Weight:	˜1.4kg 
Primary connection:	200mm fly leads
Secondary connection:	Solder tags
 |  | Powertran EI-Core 240V AC mains transformer with 6.6A dual multi tapped secondary configuration. Two sets of 0V, 9V and 12V secondaries are available at a maximum current of 6.6A (max current when 9V secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for A | 
|  | M2170C  NEW
  |  | Primary Voltage:	240V AC
Total VA Rating:	100VA
Insulation:	Class E (120°C)
Magnetising Current:	<85mA
Temperature Rise:	<70°C
Regulation:	˜14%
Recommended primary AC Fuse: 	500mA
Weight:	˜1.6kg
Primary connection:	200mm fly leads
Secondary connection:	Solder tags
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
 |  | Powertran EI-Core 240V AC mains transformer with 6A dual multi tapped secondary configuration. Two sets of 0V, 12V and 15V secondaries are available at a maximum current of 6A (max current when secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS | 
|  | M2170L    |  | Primary Voltage:	240V AC
Total VA Rating:	100VA
Insulation:	Class E (120°C)
Magnetising Current:	<85mA
Temperature Rise:	<70°C
Regulation:	˜14%
Recommended primary AC Fuse: 	500mA
Weight:	˜1.6kg
Primary connection:	200mm fly leads
Secondary connection:	Solder tags
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
 |  | Powertran EI-Core 240V AC mains transformer with 6A dual multi tapped secondary configuration. Two sets of 0V, 12V and 15V secondaries are available at a maximum current of 6A (max current when secondaries connected in parallel) . Primary is fitted with 200mm flyleads. Secondary taps have solder tags. Fully electrical authority approved for AS/NZS | 
|  | M2190C  NEW
  |  | Primary voltage: 240V AC
Total VA rating: 120VA
Insulation: Class E (120°C)
Magnetising current: <85mA
Temperature rise: <65°C
Regulation: ≈10%
Recommended primary AC fuse: 500mA
Weight: ≈1.4kg
Primary connection: 200mm fly leads
Secondary connection: 200mm fly leads
 |  | Powertran EI-Core 240V AC mains transformer with 5A single tap secondary configuration. | 
|  | M2190L    |  | Primary voltage:	240V AC
Total VA rating:	120VA
Insulation:	Class E (120°C)
Magnetising current:	<85mA
Temperature rise:	<65°C
Regulation:	˜10%
Recommended primary AC fuse: 	500mA
Weight:	˜2.2kg
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
AS/NZS 61558.2.6 approval:	Q042094
AS3108 approval:	CS/990/Q
 |  | Primary fitted with 200mm fly leads.  Secondary taps have solder tags. | 
|  | M2851C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	1.89VA
Insulation:	Class E (120°C)
Magnetising current:	<30mA
Temperature rise:	<65°C
Regulation:	˜7.5%
AC fuse:	Not required (fitted internally)
Weight:	˜145g
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M2852C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	3.78VA
Insulation:	Class E (120°C)
Magnetising current:	<40mA
Temperature rise:	<65°C
Regulation:	˜12%
AC fuse:	Not required (fitted internally)
Weight:	˜235g
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M2852L    |  | Primary voltage:	240V AC
Total VA rating:	3.78VA
Insulation:	Class E (120°C)
Magnetising current:	<40mA
Temperature rise:	<65°C
Regulation:	˜12%
AC fuse:	Not required (fitted internally)
Weight:	˜235g
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M2853C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	6.3VA
Insulation:	Class E (120°C)
Magnetising current:	<45mA
Temperature rise:	<65°C
Regulation:	˜13%
Recommended AC fuse:	100mA
Weight:	˜315g
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M2853L    |  | Primary voltage:	240V AC
Total VA rating:	6.3VA
Insulation:	Class E (120°C)
Magnetising current:	<45mA
Temperature rise:	<65°C
Regulation:	˜13%
Recommended AC fuse:	100mA
Weight:	˜315g
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
Secondary Voltages Available: Voltage : 6.3V, 12.6V / Current : 300mA
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M2854C  NEW
  |  | Primary voltage:	240V AC
Total VA rating:	3.6VA
Insulation:	Class E (120°C)
Magnetising current:	<40mA
Temperature rise:	<65°C
Regulation:	˜12%
AC fuse:	Not required (fitted internally)
Weight:	˜235g 
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M2854L    |  | Primary voltage:	240V AC
Total VA rating:	3.6VA
Insulation:	Class E (120°C)
Magnetising current:	<40mA
Temperature rise:	<65°C
Regulation:	˜12%
AC fuse:	Not required (fitted internally)
Weight:	˜235g 
Primary connection:	200mm fly leads
Secondary connection:	200mm fly leads
AS/NZS 61558.2.6 approval:	Q042028
AS3108 approval:	CS/813/Q
Secondary Voltages Available: Voltage : 12V, 24 / Current : 150mA
 |  | Primary and secondary fitted with 200mm fly leads. | 
|  | M4312A    |  | Sec. V: 6+6 
Sec. Parallel: 1.67A 
Sec. Series: 0.83A
Primary voltage: 2 x 120V AC
Total VA rating: 10VA
Insulation: Class A (105°C)
Magnetising current: <20mA
Temperature rise: <65°C
Recommended AC Fuse: 100mA
Regulation: ˜20%
Weight: ˜210g
PCB hole size: 2mm
AS/NZS 61558.2.6 approval: Q99396 
Note: Must be used with a standard 100mA external AC fuse
 |  | 6+6V 10VA Potted Toroidal Transformer. | 
|  | M4315A    |  | Sec. V: 7.5+7.5 
Sec. Parallel: 1.3A 
Sec. Series: 0.66A 
Primary voltage: 2 x 120V AC 
Total VA rating: 10VA 
Insulation: Class A (105°C) 
Magnetising current: <20mA 
Temperature rise: <65°C 
Recommended AC Fuse: 100mA 
Regulation: ˜20% 
Weight: ˜210g 
PCB hole size: 2mm 
AS/NZS 61558.2.6 approval: Q99396 
Note: Must be used with a standard 100mA external AC fuse
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4318  ROHS
  |  | Sec. V: 9+9 
Sec. Parallel: 1.1A 
Sec. Series: 0.5A 
Primary voltage: 2 x 120V AC 
Total VA rating: 10VA 
Insulation: Class A (105°C) 
Magnetising current: <20mA 
Temperature rise: <65°C 
Recommended AC Fuse: 100mA 
Regulation: ˜20% 
Weight: ˜210g 
PCB hole size: 2mm 
AS/NZS 61558.2.6 approval: Q99396 
Note: Must be used with a standard 100mA external AC fuse
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4324A    |  | 	 	 Sec. V: 12+12 
Sec. Parallel: 0.82A 
Sec. Series: 0.41A 
Primary voltage: 2 x 120V AC 
Total VA rating: 10VA 
Insulation: Class A (105°C) 
Magnetising current: <20mA 
Temperature rise: <65°C 
Recommended AC Fuse: 100mA 
Regulation: ˜20% 
Weight: ˜210g 
PCB hole size: 2mm 
Note: Must be used with a standard 100mA external AC fuse
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4330A    |  | Primary voltage: 2 x 120V AC
Total VA rating: 10VA
Insulation: Class B (130°C)
Magnetising current: <20mA
Temperature rise: <85°C
External AC fuse (required): 100mA
Thermal fuse: 84°C
Regulation: ≈20%
Weight: ≈210g
PCB hole size: 2mm
Approval:	SAA151379EA
Note: Must be used with a standard 100mA external AC fuse
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4615    |  |  |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4618A    |  | 	 Primary voltage:	2 x 120V AC
Total VA rating:	30VA
Insulation:	Class B (130°C)
Magnetising current:	<30mA
Temperature rise:	<85°C
External AC fuse (required):	250mA
Thermal Fuse:	84°C
Regulation:	≈16%
Weight:	≈450g
PCB hole size:	2mm
Approval:	SAA151379EA
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4624A    |  | Primary voltage:	2 x 120V AC
Total VA rating:	30VA
Insulation:	Class B (130°C)
Magnetising current:	<30mA
Temperature rise:	<85°C
External AC fuse (required):	250mA
Thermal Fuse:	84°C
Regulation:	≈16%
Weight:	≈450g
PCB hole size:	2mm
Approval:	SAA151379EA
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for | 
|  | M4630A    |  | 	 Primary voltage:	2 x 120V AC
Total VA rating:	30VA
Insulation:	Class B (130°C)
Magnetising current:	<30mA
Temperature rise:	<85°C
External AC fuse (required):	250mA
Thermal Fuse:	84°C
Regulation:	≈16%
Weight:	≈450g
PCB hole size:	2mm
Approval:	SAA151379EA
 |  | Toroidal transformers provide a higher output compared to traditional E-I transformers of a similar physical size. They have substantially reduced radiated hum and electrical noise, generate less heat and have much better regulation making them ideal for ideal for high performance, low noise circuits. | 
|  | M4909B    |  | Primary voltage: 240V AC
Secondary voltage:  9V (parallel), 18V (series)
Secondary current:  3.3A (parallel), 1.6A (series)
Regulation: Better than 10%
Maximum temperature rise: 75°C
Dielectric strength: 4000V for 1 Minute
Insulation class: Class B (130ºC)
Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available. 
Minimum order quantity applies.
 |  | Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. | 
|  | M4909C    |  | Low profile design is suitable for use inside our 1RU 19” rack enclosures. 
30VA series models have potted epoxy centre core for easy mounting. 
Lower electrically induced noise demanded by compact equipment.
 |  | Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. | 
|  | M4912C    |  | Supplied with mounting hardware.
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. | 
|  | M4915C    |  | Supplied with mounting hardware.
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | These 30VA transformers will fit inside our 1 Unit 19" rack cases. | 
|  | M4918B    |  | Primary voltage: 240V AC
Secondary voltage:  18V (parallel), 36V (series)
Secondary current:  1.6A (parallel), 0.8A (series)
Regulation: Better than 10%
Maximum temperature rise: 75
 |  | These 30VA transformers will fit inside our 1 Unit 19" rack cases. | 
|  | M4918C    |  | Supplied with mounting hardware.
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Low profile design suitable for use inside our 1RU 19"rack enclosures. Potted epoxy centre core for easy mounting. | 
|  | M4925C    |  | Supplied with 1 rubber washer, bolt and nut.
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | These 30VA transformers will fit inside our 1 Unit 19" rack cases. | 
|  | M5009C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Low profile design suitable for use inside our 1RU 19" rack enclosures. | 
|  | M5012C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Low profile design suitable for use inside our 1RU 19" rack enclosures. | 
|  | M5015C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | These 50VA transformers will fit inside our 1 Unit 19" rack cases | 
|  | M5018C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Low profile design suitable for use inside our 1RU 19" rack enclosures. 18+18V. | 
|  | M5025C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | These 50VA transformers will fit inside our 1 Unit 19" rack cases | 
|  | M5109    |  | Primary voltage: 240V AC
Secondary voltage: 9V (parallel), 18V (series)
Secondary current: 8.8A(parallel) 4.4A (series)
Regulation: Better than 10%
Maximum temperature rise: 75°C
Dielectric strength: 4000V for 1 Minute
Insulation class: Class B (130ºC)
Attention OEM customers: Please contact our parent company Altronic Distributors for extremely competitive wholesale pricing. Variations or custom toroidals available. 
Minimum order quantity applies.
 |  | Certificate No.: CS 815/Q | 
|  | M5109C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 9V secondaries. 80VA rated. | 
|  | M5112C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Certificate No.: CS 815/Q | 
|  | M5115C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 15V secondaries. 80VA rated. | 
|  | M5118C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 18V secondaries. 80VA rated. | 
|  | M5125C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 25V secondaries. 80VA rated. | 
|  | M5312C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Note: Must be used with a 3A external AC fuse. | 
|  | M5315C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Note: Must be used with a 3A external AC fuse. | 
|  | M5318C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | 18+18V 160VA toroidal transformer. | 
|  | M5325C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 25V secondaries. 160VA rated. | 
|  | M5345A    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 45V secondaries. 160VA rated. | 
|  | M5512C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 12V secondaries. 300VA rated. | 
|  | M5518C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | 300VA toroidal transformer | 
|  | M5525C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | 25+25V 300VA toroidal transformer. | 
|  | M5530C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 30V secondaries. 300VA rated. | 
|  | M5535C    |  | Each toroidal is supplied with 2 x rubber spacing washers, 1 x steel dished washer, 1 x mounting bolt, 1 x nut (except PCB mount versions).
Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Efficient toroidal transformer with 35V secondaries. 300VA rated. | 
|  | M5725C    |  | Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Toroidal transformers are becoming increasingly popular due to their improved magnetic properties and also that they can be made to a lower profile than a standard solenoid core transformer, allowing for equipment of similar power to be of a lower profile such as rack mounted devices. | 
|  | M5730C    |  | Lower electrically induced noise demanded by compact equipment.
High efficiency enabling conservative rating whilst maintaining size advantages.
The toroidal transformer is accepted as the industry standard, replacing the laminated type as toroidal transformers offer advantages in size, weight, and lower radiated field.
 |  | Toroidal transformers are becoming increasingly popular due to their improved magnetic properties and also that they can be made to a lower profile than a standard solenoid core transformer, allowing for equipment of similar power to be of a lower profile such as rack mounted devices. | 
|  | M6010    |  |  |  | Typically used for garden lighting and water feature pumps these power supplies are ideal for outdoor use. | 
|  | M6014    |  |  |  | Typically used for garden lighting and water feature pumps these power supplies are ideal for outdoor use. | 
|  | M6672C  NEW
  |  | Primary voltage: 240V AC
Total VA rating: 30VA
Insulation: Class E (120°C)
Magnetising current: <80mA
Temperature rise: <65°C
Regulation: ˜8%
Recommended primary AC fuse: 500mA
Weight: ˜1kg
Primary connection: 200mm fly leads
Secondary connection: Solder tags
AS/NZS 61558.2.6 approval: Q042029
AS3108 approval:	CS/814/Q
 |  | Primary fitted with 200mm fly leads.  Secondary taps have solder tags. | 
|  | M6672L    |  | Primary voltage: 240V AC
Total VA rating: 30VA
Insulation: Class E (120°C)
Magnetising current: <80mA
Temperature rise: <65°C
Regulation: ˜8%
Recommended primary AC fuse: 500mA
Weight: ˜1kg
Primary connection: 200mm fly leads
Secondary connection: Solder tags
AS/NZS 61558.2.6 approval: Q042029
AS3108 approval:	CS/814/Q
 |  | Primary fitted with 200mm fly leads.  Secondary taps have solder tags. | 
|  | M7012A  ROHS
  |  | 	 Sec. V: 6+6 
Sec. Parallel: 0.5A 
Sec. Series: 0.25A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 3VA
Insulation: Class B (130°C)
Magnetising current: <20mA
Temperature rise: <65°C
Regulation: ˜23%
Weight: ˜95g
PCB hole size: 0.8mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7015A  ROHS
  |  | 	 Sec. V: 7.5+7.5 
Sec. Parallel: 0.4A 
Sec. Series: 0.20A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 3VA
Insulation: Class B (130°C)
Magnetising current: <20mA
Temperature rise: <65°C
Regulation: ˜23%
Weight: ˜95g
PCB hole size: 0.8mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7018A  ROHS
  |  | 	 Sec. V: 9+9
Sec. Parallel: 0.33A 
Sec. Series: 0.16A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 3VA
Insulation: Class B (130°C)
Magnetising current: <20mA
Temperature rise: <65°C
Regulation: ˜23%
Weight: ˜95g
PCB hole size: 0.8mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7024A  ROHS
  |  | 	 Sec. V: 12+12 
Sec. Parallel: 0.25A 
Sec. Series: 0.125A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 3VA
Insulation: Class B (130°C)
Magnetising current: <20mA
Temperature rise: <65°C
Regulation: 23%
Weight: 95g
PCB hole size: 0.8mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7030A  ROHS
  |  | 	 Sec. V: 15+15 
Sec. Parallel: 0.2A 
Sec. Series: 0.10A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 3VA
Insulation: Class B (130°C)
Magnetising current: <20mA
Temperature rise: <65°C
Regulation: ˜23%
Weight: ˜95g
PCB hole size: 0.8mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7052A  ROHS
  |  | 	 Sec. V: 6+6 
Sec. Parallel: 0.83A 
Sec. Series: 0.41A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 5VA
Insulation: Class B (130°C)
Magnetising current: <30mA
Temperature rise: <65°C
Regulation: ˜20%
Weight: ˜175g
PCB hole size: 1mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7055A  ROHS
  |  | 	 Sec. V: 7.5+7.5 
Sec. Parallel: 0.66A 
Sec. Series: 0.33A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 5VA 
Insulation: Class B (130°C) 
Magnetising current: <30mA 
Temperature rise: <65°C 
Regulation: 20% 
Weight: 175g 
PCB hole size: 1mm 
Thermal Fuse: Internal 115°C 
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7058A  ROHS
  |  | 	 Sec. V: 9+9 
Sec. Parallel: 0.55A 
Sec. Series: 0.27A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 5VA 
Insulation: Class B (130°C) 
Magnetising current: <30mA 
Temperature rise: <65°C 
Regulation: 20% 
Weight: 175g 
PCB hole size: 1mm 
Thermal Fuse: Internal 115°C 
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7064A  ROHS
  |  | 	 Sec. V: 12+12 
Sec. Parallel: 0.416A 
Sec. Series: 0.208A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 5VA 
Insulation: Class B (130°C) 
Magnetising current: <30mA 
Temperature rise: <65°C 
Regulation: 20% 
Weight: 175g 
PCB hole size: 1mm 
Thermal Fuse: Internal 115°C 
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7070A  ROHS
  |  | 	 Sec. V: 15+15 
Sec. Parallel: 0.333A 
Sec. Series: 0.16A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 5VA 
Insulation: Class B (130°C) 
Magnetising current: <30mA 
Temperature rise: <65°C 
Regulation: 20% 
Weight: 175g 
PCB hole size: 1mm 
Thermal Fuse: Internal 115°C 
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7112A  ROHS
  |  | Sec. V: 6+6
Sec. Parallel: 1.166A
Sec. Series: 0.58A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 7VA
Insulation: Class B (130°C)
Magnetising current: <30mA
Temperature rise: <65°C
Recommended AC Fuse: 100mA
Regulation: 11%
Weight: 265g
PCB hole size: 1mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7115A  ROHS
  |  | Sec. V: 7.5+7.5
Sec. Parallel: 0.933A
Sec. Series: 0.46A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 7VA
Insulation: Class B (130°C)
Magnetising current: <30mA
Temperature rise: <65°C
Recommended AC Fuse: 100mA
Regulation: ˜11%
Weight: ˜265g
PCB hole size: 1mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7118A  ROHS
  |  | Sec. V: 9+9
Sec. Parallel: 0.77A
Sec. Series: 0.38A
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 7VA
Insulation: Class B (130°C)
Magnetising current: <30mA
Temperature rise: <65°C
Recommended AC Fuse: 100mA
Regulation: ˜11%
Weight: ˜265g
PCB hole size: 1mm
Thermal Fuse: Internal 115°C
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7124A  ROHS
  |  | 	 Sec. V: 12+12 
Sec. Parallel: 0.58A 
Sec. Series: 0.29A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 7VA 
Insulation: Class B (130°C) 
Magnetising current: <30mA 
Temperature rise: <65°C 
Recommended AC Fuse: 100mA 
Regulation: 11% 
Weight: 265g 
PCB hole size: 1mm 
Thermal Fuse: Internal 115°C 
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7130A  ROHS
  |  | Sec. V: 15+15 
Sec. Parallel: 0.466A 
Sec. Series: 0.233A 
Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA rating: 7VA 
Insulation: Class B (130°C) 
Magnetising current: <30mA 
Temperature rise: <65°C 
Recommended AC Fuse: 100mA 
Regulation: 11% 
Weight: 265g 
PCB hole size: 1mm 
Thermal Fuse: Internal 115°C 
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7152  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 7VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 265g 
PCB Hole Size: 1.2mm
Secondary Voltage: 6 + 6
Parallel : 1.166A
Series: 0.58A
Standard AS/NZS 61558.2.6 Certified
 |  | Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7155  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 7VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 265g 
PCB Hole Size: 1.2mm
Secondary Voltage: 7.5 + 7.5
Parallel : 0.933A
Series: 0.46A
Standard AS/NZS 61558.2.6 Certified
 |  | Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7158  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 7VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 265g 
PCB Hole Size: 1.2mm
Secondary Voltage: 9 + 9
Parallel : 0.77A
Series: 0.38A
Standard AS/NZS 61558.2.6 Certified
 |  | Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7164  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 7VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 265g 
PCB Hole Size: 1.2mm
Secondary Voltage: 12 + 12
Parallel : 0.58A
Series: 0.29A
Standard AS/NZS 61558.2.6 Certified
 |  | Physical dimensions compatible with Arlec/Stadium series Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7252  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 10VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 250g 
PCB Hole Size: 1.2mm
Secondary Voltage: 6 + 6 
Parallel : 1.66A 
Series: 0.83A
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7255  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 10VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 250g 
PCB Hole Size: 1.2mm
Secondary Voltage: 7.5 + 7.5 
Parallel : 1.33A 
Series: 0.66A
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7258  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 10VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 250g 
PCB Hole Size: 1.2mm
Secondary Voltage: 9 + 9 
Parallel : 1.1A 
Series: 0.55A
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7264  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 10VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 250g 
PCB Hole Size: 1.2mm
Secondary Voltage: 12 + 12
Parallel : 0.83A 
Series: 0.41A
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. | 
|  | M7270  ROHS
  |  | Primary voltage: 230V AC or 240V AC @ 50Hz
Total VA Rating: 10VA 
Insulation: Class A (105°C) 
Magnetising Current: <30mA 
Temperature Rise: <65°C 
Regulation: 11% 
Weight: 250g 
PCB Hole Size: 1.2mm
Secondary Voltage: 15 + 15
Parallel : 0.66A 
Series: 0.33A
Standard AS/NZS 61558.2.6 Certified
 |  | Manufactured using very high quality grain oriented silicon steel. This results in a compact, high performance, high output transformer. |